Hnt-1000A Medical Equipment Infant Radiant Warmer

Model NO.: HNT-1000A
Medical Devices Reg./Record No.: Gsyjxzz20123540587
Mattress to Radiant Box: 81 Cm
Environment Relative Humidity: 30%~75%
Temperature Control Mode: Auto
Mattress Tray Size: 68cm×56cm
Certificate: CE, ISO
Trademark: Healicom
Transport Package: Carton
Specification: CE, ISO
Origin: Jiangsu, China
HS Code: 9018909090
Model NO.: HNT-1000A
Medical Devices Reg./Record No.: Gsyjxzz20123540587
Mattress to Radiant Box: 81 Cm
Environment Relative Humidity: 30%~75%
Temperature Control Mode: Auto
Mattress Tray Size: 68cm×56cm
Certificate: CE, ISO
Trademark: Healicom
Transport Package: Carton
Specification: CE, ISO
Origin: Jiangsu, China
HS Code: 9018909090
Hnt-1000A Medical Equipment Infant Radiant Warmer
STANDARD COMPOSITION
1.        Servo Control Mode: air temperature
2.        Instant Parameter Display: set temp, skin temp, heat power rate;
3.        Audible/Visual Alarms: temp deviation, sensor failure, power failure, temp override;
4.        Tilting Bed with Rotary Radiant Head
5.        X-ray Cassette Tray under infant bed, examination light of high illuminance
6.        Use anti-blast quartz infrared tube as radiant heating source.


TECHNICAL SPECIFICATION
Power Model HNT-1000-1E AC 110 / 120 V, 50Hz / 60Hz
Model HNT-1000-2E AC 220 / 240V, 50Hz / 60Hz
Input Power ≤1000VA
Temperature control range and relative specification Control mode Auto mode
Temperature control range 25°C~37°C.
Skin temperature sensor measure range 20°C~42°C
Deviation between sensor measure temperature and control temperature ≤0.5°C
Skin Sensor Precision ≤0.3°C
Bed surface temperature Uniformity ≤1°C
Temperature Rise Time ≤45min
Bed tiltable continues adjustable in ±10°
Alarm Sensor failure alarm Alarm with audible and visual when sensor open circuit, short circuit or disconnect, cut off power.
Over temperature alarm Alarm with audible and visual when displayed temperature was approach 38°C.
Deviation alarm After temperature equilibrium, alarm with audible and visual when displayed temperature was 1°C above or below control temperature, cut off power if above 1°C.
Power failure alarm Alarm with audible and visual when power failure
Environment Temperature
(It is a suggestion that please do not use outside of the allow environment.)
Operate temperature range 18°C~30°C
Store temperature range -20°C~+55°C
Environment Humidity Operate humidity range 30%RH~75%RH
Store humidity range ≤93%RH
Atmospheric pressure Transport and Store atmospheric pressure range 500hPa~1060hPa
Operate atmospheric pressure range 700hPa~1060hPa
Stream velocity Ambit environment stream velocity ≤0.3m/s

HNT-1000A : Based on HNT-1000, 1000A Add: Intra-low-pressure suction machine Hnt-1000A Medical Equipment Infant Radiant Warmer
STANDARD COMPOSITION
1.        Servo Control Mode: air temperature
2.        Instant Parameter Display: set temp, skin temp, heat power rate;
3.        Audible/Visual Alarms: temp deviation, sensor failure, power failure, temp override;
4.        Tilting Bed with Rotary Radiant Head
5.        X-ray Cassette Tray under infant bed, examination light of high illuminance
6.        Use anti-blast quartz infrared tube as radiant heating source.


TECHNICAL SPECIFICATION
Power Model HNT-1000-1E AC 110 / 120 V, 50Hz / 60Hz
Model HNT-1000-2E AC 220 / 240V, 50Hz / 60Hz
Input Power ≤1000VA
Temperature control range and relative specification Control mode Auto mode
Temperature control range 25°C~37°C.
Skin temperature sensor measure range 20°C~42°C
Deviation between sensor measure temperature and control temperature ≤0.5°C
Skin Sensor Precision ≤0.3°C
Bed surface temperature Uniformity ≤1°C
Temperature Rise Time ≤45min
Bed tiltable continues adjustable in ±10°
Alarm Sensor failure alarm Alarm with audible and visual when sensor open circuit, short circuit or disconnect, cut off power.
Over temperature alarm Alarm with audible and visual when displayed temperature was approach 38°C.
Deviation alarm After temperature equilibrium, alarm with audible and visual when displayed temperature was 1°C above or below control temperature, cut off power if above 1°C.
Power failure alarm Alarm with audible and visual when power failure
Environment Temperature
(It is a suggestion that please do not use outside of the allow environment.)
Operate temperature range 18°C~30°C
Store temperature range -20°C~+55°C
Environment Humidity Operate humidity range 30%RH~75%RH
Store humidity range ≤93%RH
Atmospheric pressure Transport and Store atmospheric pressure range 500hPa~1060hPa
Operate atmospheric pressure range 700hPa~1060hPa
Stream velocity Ambit environment stream velocity ≤0.3m/s

HNT-1000A : Based on HNT-1000, 1000A Add: Intra-low-pressure suction machine